030239(2000W)Owner’s ManualManuel de l'utilisateurManual del PropietarioBRIGGS & STRATTON POWER PRODUCTS GROUP, LLCJEFFERSON, WISCONSIN, U.S.
2000W Generator106. Slide the choke lever left to the “Run” position as theengine warms up.NOTE: Under no load conditions, the engine speed mayvary sl
2000W Generator116. Connect battery charge cable clamp with black handleto battery post or terminal indicated by Negative,NEG, or (–) (Figure 8).7. St
2000W Generator12In an emergency, use the original shipping carton as atemporary shelter:7. Cut off all carton flaps.8. Cut out one long side of carto
2000W Generator13DON'T OVERLOADGENERATORCapacityYou must make sure your generator can supply enoughrated (running) and surge (starting) watts for
2000W Generator14ENGINE TECHNICALINFORMATIONThis is a single cylinder, overhead valve(OHV), air cooledengine. It is a low emissions engine.In the Stat
GENERALRECOMMENDATIONSRegular maintenance will improve the performance andextend the life of the generator. See any authorized Briggsand Stratton Powe
2000W Generator16• Use a damp cloth to wipe exterior surfaces clean.• Use a soft bristle brush to loosen caked on dirt, oil, etc.• Use a vacuum cleane
2000W Generator175. Check electrode gap with wire feeler gauge and setspark plug gap to 0.030 inch (0.76 mm) if necessary(Figure 15).6. Reinstall spar
2000W Generator18STORAGE INSTRUCTIONSThe generator should be started at least once every sevendays and allowed to run at least 30 minutes. If this can
2000W Generator19TROUBLESHOOTINGProblem Cause CorrectionEngine is running, but noAC output is available.1. One of the circuit breakers is open.2. Faul
2000W Generator2TABLE OF CONTENTSSafety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4Know Your Generator . . . . .
2000W Generator20NOTES
2000W Generator21NOTES
EMISSION CONTROL SYSTEM WARRANTYIn the interest of the environment, MHI engines that meet strictemission requirements are labeled, “This ULGE conforms
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICYLIMITED WARRANTYBriggs & Stratton Power Products Group, LLC will re
2000W Generator3• DO NOT allow any open flame, spark, heat, or lit cigaretteduring and for several minutes after charging a battery.• Wear protective
2000W Generator4• DO NOT tamper with governed speed. Generator suppliescorrect rated frequency and voltage when running at governedspeed.• DO NOT modi
2000W Generator512 Volt DC, 8.3 Amp Accessory Jacks — May be usedto power 12 Volt DC electrical devices or recharge 12 VoltDC batteries.120 Volt AC, 1
2000W Generator6ASSEMBLYYour generator requires some assembly and is ready foruse after it has been properly serviced with therecommended oil and fuel
1. Choose a viscosity according to the table below:* The use of multi-viscosity oils (5W-30, 10W-30, etc.) intemperatures above 40°F (4°C) will result
2000W Generator8USING THE GENERATORSystem GroundThe generator has a system ground that connects thegenerator frame components to the ground terminals
OPERATING THEGENERATORStarting the EngineDisconnect all electrical loads from the generator. Use thefollowing start instructions:1. Make sure unit is
Comentarios a estos manuales