OPERATION
Startup Checklist
Use the following checklist to verify the correct preparation of your engine generator
before starting.
On all units check:
1.
Engine oil-fill as required with correct grade and quantity.
2.
Check fuel level-fill with clean fresh fuel as required.
3.
Visually check unit for loose parts.
4.
Ventilation. (DO NOT operate indoors. Exhaust gases are deadly.)
Starting
1.
Refer to engine operator's manual for the location of the choke. Close the choke
.
lever completely to start a cold engine. When restarting a warm engine, close the
choke halfway.
'
NOTE: Avoid overchoking. Don't leave the choke in the closed position after the
engine starts. It may not be necessary to choke the engine when it is warm.
2.
Manual Start: Pull the recoil starter Slightly and when compression is felt, give
the starter rope a sharp, vigorous pull.
DO NOT change engine speed settings..The engine speed has been preset at the
factory for
3600
RPM operation and the governor speed control tightened to prevent
slipping. Operating the engine at a higher or lower speed can result in engine,
generator or other equipment damage.
3.
Operation: It is a good practice to allow the engine to run for
2
to
3
minutes before
applying a load to the generator. This enables the engine to warm up and the oil
to thoroughly circulate throughout the engine.
A
short warm-up time will permit
the engine to work more efficiently when the load is applied and will reduce the
wear in the engine, extending its life.