STARTER MOTOR CURRENT DRAW
120 VOLT STARTER MOTORS A
Use Line Current Adapter, Tool part number 19358,
when checking current draw on 120 volt starter
motors. Use the same test xture used in the 12
volt starter test to check the current draw and free
running RPM of motor.
The following test procedure must be
used to avoid any accidental shock
hazard to the service technician.
1. Insert BLACK test lead from adapter, Tool part
number 19358, into the
COM
receptacle in
meter.
2. Insert white test lead from adapter, Tool part
number 19358, into the
receptacle in
meter.
3. Plug the adapter cord (female end) into the switch
box receptacle of the starter motor.
4. Plug the adapter cord (male end) into the
previously tested wall outlet.
5. Rotate selector to A
position.
6. Refer to specications, Table 4, and note
maximum allowable amperage draw for motor
being tested.
7. Depress starter switch button. When meter
reading stabilizes, (approximately 3 seconds)
amperage should not exceed the specication
shown in Table 4.
CAUTION: If amperage is higher than
specication in Table 4, immediately
stop the test! An amperage reading
higher than number in chart, indicates
a shorted starter motor, which could be
dangerous.
120 Volt AC Starter Motor Current Draw
with Line Current Adapter
8. If starter motor amperage is within specication,
check RPM using vibration tachometer, Tool part
number 19200.
9. RPM should be close to specications listed in
Table 4.
10. If the starter motor does not meet the given
specications, refer to the Repair Instructions
Manual, Section 7.
TABLE 4
120 VOLT STARTER MOTOR SPECIFICATIONS
STARTER MOTOR
IDENTIFICATION
MAXIMUM
AMPERAGE
MINIMUM
RPM
American Bosch
SME–110–C3
SME–110–C6
SME–110–C8
3.5 7400
American Bosch
06026–28–M030SM
3.0 7400
Mitsubishi
J282188
3.5 7800
Briggs & Stratton
3-1/2˝ (75.45 mm) Motor Housing
2.7 6500
PUSH
SWITCH TO
ACTIVATE
STARTER
TACHOMETER
READ RPM OF
STARTER MOTOR
AC LINE VOLTAGE MUST
BE NO LESS THAN 110 VOLTS
another free manual from www.searstractormanuals.com