WIRE IDENTIFICATION REFERENCE
TERMINAL ENGINE TERMINATION POINT
A CYLINDER #1 COIL
B CYLINDER #2 COIL
C CARB SOLENOID
D GROUND
E POWER SUPPLY TO REGULATOR
F EFM IGNITION PULSE
6 PIN
CONNECTOR
CYL. 1
CYL. 2
CURRENT FLOW
2
1
SEE DETAIL K
1
2
3
4
C
B
F
DETAIL
K
6
14
15
14
EACH DIODE ASSEMBLY MUST BE INDIVIDUALLY WRAPPED
IN SHRINK TUBING. AN ADDITIONAL SHRINK WRAP MUST
ALSO BE ASSEMBLED OVER BOTH DIODE ASSEMBLIES.
"ROUTE" TO TERMINAL
HOLE No's AS SHOWN.
JUMPER WIRE
BETWEEN 1&4
1
2
3
4
5
6
SOCKETS MUST BE PUSHED INTO
HOUSING UNTIL TANGS SNAP
OPEN OVER PLASTIC TO
INSURE THAT SOCKETS CANNOT
BACK OUT (4 PLACES)
RIB
3
2
9
A
D
E
E
4
6
5
DETAIL “K” KEY
6 DIODES
14
CRIMPED CONNECTION
15 SHRINK TUBING