7
DC SHUNT INSTRUCTIONS
The DC shunt, part number 19468 readily adapts
to standard mount, side mount or tab type battery
terminals. The shunt must be installed on the
- (negative) terminal of the battery.
For standard terminals, attach ring terminal on shunt
to post terminal on battery. For tab terminal batteries,
attach shunt to battery terminal using 1/4
" – 20 stud
and wing nut. For side terminal batteries, remove
post terminal from shunt and thread into side terminal
on battery. Attach battery cable to shunt using
3/8" – 16 nut from post terminal.
The Digital Multimeter will withstand DC input of
10 – 20 Amps for up to 30 seconds. To avoid blowing
fuse in meter, use the DC shunt when checking
current draw of 12 volt starter motors or DC output
on 16 Amp regulated alternator.
Charging output can be checked with the engine
running. All connections must be clean and tight for
correct amperage readings.
1. Install shunt on negative battery terminal.
2. Insert RED test lead into v receptacle in
meter and RED receptacle on shunt.
3. Insert BLACK test lead into
receptacle in
meter and BLACK receptacle on shunt.
4. Rotate selector switch to
position.
Standard Mount Tab Mount Side Mount
NEGATIVE BATTERY
TERMINAL
ATTACH NEGATIVE
BATTERY CABLE
LEAD
LEAD
NEGATIVE
BATTERY
TERMINAL
NEGATIVE BATTERY
TERMINAL
ATTACH
NEGATIVE
BATTERY
CABLE WITH
3/8"-16 NUT
ATTACH NEGATIVE
BATTERY CABLE
NEGATIVE BATTERY
TERMINAL
another free manual from www.searstractormanuals.com
Comentarios a estos manuales